By device
Tablet screen test
A tablet sits between a phone and a laptop, and it fails like both: burn-in in one orientation, pressure marks from a keyboard cover, and a digitiser that handles a pen differently from a finger.
Last updated
Before you start
- Turn off automatic brightness and any adaptive colour setting. A tablet that rebalances itself while you look at a flat field makes every judgement worthless.
- Remove the case and any screen protector if you can. A protector with trapped air produces touch dead spots that look exactly like a digitiser fault.
- Clean the glass. A tablet is held, propped and leaned on more than a phone, so the surface collects more than you expect.
- Test in both orientations. A tablet is used in portrait and landscape, and some faults are far more visible in one than the other.
- Have the stylus to hand if the tablet supports one. Pen tracking and finger tracking use the same digitiser and can fail separately.
The run, in order
- 01 Dead pixel test
Nine fields. A tablet panel is large enough that a single dead pixel is visible at normal distance, unlike a phone, so this is worth doing carefully.
- 02 Multi touch test
How many contacts the digitiser tracks at once. Tablets are where this matters most, because two-handed gestures and stylus work both depend on it.
- 03 Touch screen test
The grid for dead zones and the drawing mode for drift. Run the stylus through the drawing mode as well as a finger, since they can behave differently.
- 04 OLED burn-in test
On an OLED tablet, check where the keyboard, dock and status bar sit. A tablet used mostly in one orientation wears unevenly in that orientation.
- 05 Screen uniformity test
Grey fields across a large panel. Tablets are big enough for uniformity to matter and small enough that people rarely check it.
- 06 Backlight bleed test
On an LCD tablet, bleed at the edges is common and is worsened by pressure from a case or a firm grip on one corner.
- 07 Screen resolution test
Confirm what the browser reports, which on a tablet is usually a scaled value. It also tells you the device pixel ratio, which decides whether the pixel-exact tests can run.
What matters on this hardware
Touch dead spots under a protector
A screen protector with trapped air or a poor fit reduces sensitivity in patches. If touch problems appeared when you fitted one, remove it and map the panel again before blaming the tablet.
Stylus and finger tracking differ
Many tablets reject finger contacts while a pen is near the screen, which is palm rejection doing its job. A pen that jitters while a finger tracks cleanly points at the pen or its tip rather than the digitiser.
Burn-in in one orientation
A tablet used mostly in landscape for video and mostly in portrait for reading wears differently in each. Check flat fields in both orientations, because a ghost that is invisible one way round can be obvious the other.
Pressure marks from a keyboard cover
A folio keyboard presses against the panel when closed, exactly as a laptop lid does. The result is a row of faint marks visible on grey, and it is damage rather than a manufacturing fault.
Refresh rate that drops on static content
Adaptive refresh rate on a high rate tablet drops to a low figure while nothing moves, to save battery. Measuring while the screen is still gives you that low figure rather than the maximum.
Fractional pixel ratio blocks some tests
Several tablets run at a device pixel ratio that is not a whole number, which means the single-pixel pattern tests refuse rather than showing a resampled result. That is the tests being honest, not a fault.
Questions people actually ask
Is a tablet tested the same way as a phone?
Mostly, with two differences. The panel is large enough that uniformity and dead pixels are easier to see at normal distance, and stylus support adds a second input path that can fail independently of touch. Both are worth an extra minute.
My stylus skips or jitters near the edge. Is the tablet faulty?
Edge behaviour is worse on almost every digitiser, because the sensing grid has no neighbours to interpolate from beyond the boundary. Some falloff in the last few millimetres is normal. Skipping well inside the panel is not.
Should I test with the case on or off?
Off, for the panel itself. Then put the case back and run the touch grid again. A case that presses on the edges of the glass can cause touch problems that disappear the moment you remove it, which is useful to know before you arrange a repair.
Why does the gamma test refuse to run on my tablet?
Because the device pixel ratio is not a whole number on many tablets, so the single-pixel line pattern gets resampled before it reaches the panel. The test says it cannot measure rather than showing a wrong answer. The greyscale and near-black tests work at any ratio.
How do I check a second-hand tablet quickly?
Dead pixels, burn-in on a flat grey field, and the touch grid. Those three find the expensive faults in under five minutes, and all three work with no network connection once the site has loaded once.